Human IL-27 IQELISA™ Kit
RayBio® Human Immunoquantitative (PCR-Based) IL-27 ELISA Kit for cell culture supernatants, plasma, and serum samples.
Specifications
Size |
1 Plate Kit, 2 Plate Kit, 5 Plate Kit |
---|---|
Species |
Human |
Quantitative/Semi-Quantitative |
Quantitative |
Protein Name / Synonyms |
Interleukin-27 subunit alpha (IL-27 subunit alpha) (IL-27-A) (IL27-A) (Interleukin-30) (p28) |
Accession Number |
Q8NEV9 |
Gene Symbols |
IL27|IL27A|IL30 |
Gene Id |
246778 |
Compatible Sample Types |
Cell Culture Supernatants, Plasma, Serum |
Solid Support |
96-well Microplate **The PCR plate used is a 0.2mL, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600) |
Method Of Detection |
qPCR |
Design Principle |
Sandwich-based |
Sensitivity |
7.8 pg/ml |
Detection Range |
10.9 pg/ml - 8,000 pg/ml |
Recommended Dilution (Serum/Plasma) |
2 - 20 fold |
Application Notes
Kit Components
- IL-27 Microplate (Item A)**: 96 well PCR plate coated with anti-Human IL-27
- Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
- Standards (Item C): 2 vials of recombinant Human IL-27
- Assay Diluent B (Item E): 15 ml of 5x concentrated buffer
- Detection Affinity Reagent for IL-27 (Item F): 2 vials of a 4x concentrated solution of anti-Human IL-27 affinity reagent
- IQELISA™ Detection Reagent (Item G): 1 ml of a 10x concentrated stock
- Primer Solution (Item I): 1.5 ml vial
- PCR Master Mix (Item J): 1.4 ml vial
- PCR Preparation buffer (Item K): 1 ml vial of 10x concentrated buffer
- Final Wash Buffer (Item L): 10 ml vial of 10x concentrated buffer
**The PCR plate used is a 0.2 ml, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600). Please ensure compatibility with your PCR machine prior to purchase. For additional information contact technical support (cs@medikonia.com).
Other Materials Required
- Real-time PCR instrument, Bio-Rad recommended
- Precision pipettes to deliver 2 µl to 1 ml volumes
- Adjustable 1-25 ml pipettes for reagent preparation
- 100 ml and 1 liter graduated cylinders
- Absorbent paper
- Distilled or deionized water
- Log-log graph paper or computer and software for data analysis
- Tubes to prepare standard or sample dilutions
- Heating block or water bath capable of 80°C
Protocol Outline
1. Prepare all reagents, samples and standards as instructed
2. Add 25 µl standard or sample to each well. Incubate for 1.5 - 2.5 hours at room temperature
3. Add 25 µl detection antibody to each well. Incubate 1 hour at room temperature
4. Add 25 µl of IQELISA™ Detection Reagent to each well. Incubate 1 hour
5. Add 10 µl Primer solution and 10 µl of PCR master mix to each well
6. Run real-time PCR
Storage/Stability
May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
Catalog #: IQH-IL27-1 -- 1 Plate Kit
Catalog #: IQH-IL27-2 -- 2 Plate Kit
Catalog #: IQH-IL27-5 -- 5 Plate Kit
Please email us at cs@medikonia.com for any enquiry. To place an order, please include the catalog number(s) of the product(s) in the email.