Mouse MIP-1 beta/CCL4 IQELISA™ Kit
RayBio® Mouse Immunoquantitative (PCR-Based) MIP-1 beta (CCL4 ELISA Kit for cell culture supernatants, plasma, and serum samples.
Specifications
Size |
1 Plate Kit, 2 Plate Kit, 5 Plate Kit |
---|---|
Species |
Mouse |
Quantitative/Semi-Quantitative |
Quantitative |
Protein Name / Synonyms |
C-C motif chemokine 4 (Immune activation protein 2) (ACT-2) (ACT2) (Macrophage inflammatory protein 1-beta) (MIP-1-beta) (Protein H400) (SIS-gamma) (Small-inducible cytokine A4) |
Accession Number |
P14097 |
Gene Symbols |
CCL4|SCYA4|MIP1B |
Gene Id |
20303 |
Compatible Sample Types |
Cell Culture Supernatants, Plasma, Serum |
Solid Support |
96-well Microplate **The PCR plate used is a 0.2mL, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600) |
Method Of Detection |
qPCR |
Design Principle |
Sandwich-based |
Sensitivity |
0.97 pg/ml |
Detection Range |
1.37 pg/ml - 1,000 pg/ml |
Recommended Dilution (Serum/Plasma) |
2 fold |
Introduction
The RayBio® Immuno Quantitative Enzyme Linked ImumunoSorbent Assay (IQELISA™) is an innovative new assay that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of lower sample volumes while also providing more sensitivity. The RayBio® Mouse MIP-1 beta (CCL4 IQELISA™ Kit is a modified ELISA assay with high sensitivity qPCR readout for the quantitative measurement of Mouse MIP-1 beta (CCL4 in serum, plasma, and cell culture supernatants. This assay employs an antibody specific for Mouse MIP-1 beta (CCL4 coated on a 96-well PCR plate. Standards and samples are pipetted into the wells and MIP-1 beta (CCL4 present in a sample is bound to the wells by the immobilized antibody. The wells are washed and a detection affinity molecule is added to the plates. After washing away unbound detection affinity molecule, primers and a PCR master mix are added to the wells and data is collected using qPCR. Ct values obtained from the qPCR are then used to calculate the amount of antigen contained in each sample, where lower Ct values indicate a higher concentration of antigen.
Standard Curve
Typical Data
Application Notes
Kit Components
- MIP-1 beta (CCL4 Microplate (Item A)**: 96 well PCR plate coated with anti-Mouse MIP-1 beta (CCL4
- Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
- Standards (Item C): 2 vials of recombinant Mouse MIP-1 beta (CCL4
- Assay Diluent B (Item E): 15 ml of 5x concentrated buffer
- Detection Affinity Reagent for MIP-1 beta (CCL4 (Item F): 2 vials of a 4x concentrated solution of anti-Mouse MIP-1 beta (CCL4 affinity reagent
- IQELISA™ Detection Reagent (Item G): 1 ml of a 10x concentrated stock
- Primer Solution (Item I): 1.5 ml vial
- PCR Master Mix (Item J): 1.4 ml vial
- PCR Preparation buffer (Item K): 1 ml vial of 10x concentrated buffer
- Final Wash Buffer (Item L): 10 ml vial of 10x concentrated buffer
**The PCR plate used is a 0.2 ml, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600). Please ensure compatibility with your PCR machine prior to purchase. For additional information contact technical support (cs@medikonia.com).
Other Materials Required
- Real-time PCR instrument, Bio-Rad recommended
- Precision pipettes to deliver 2 µl to 1 ml volumes
- Adjustable 1-25 ml pipettes for reagent preparation
- 100 ml and 1 liter graduated cylinders
- Absorbent paper
- Distilled or deionized water
- Log-log graph paper or computer and software for data analysis
- Tubes to prepare standard or sample dilutions
- Heating block or water bath capable of 80°C
Protocol Outline
Prepare all reagents, samples and standards as instructed
Add 25 µl standard or sample to each well. Incubate for 1.5 - 2.5 hours at room temperature
Add 25 µl detection antibody to each well. Incubate 1 hour at room temperature
Add 25 µl of IQELISA™ Detection Reagent to each well. Incubate 1 hour
Add 10 µl Primer solution and 10 µl of PCR master mix to each well
Run real-time PCR
Storage/Stability
May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
Catalog #: IQM-MIP1b-1 -- 1 Plate Kit
Catalog #: IQM-MIP1b-2 -- 2 Plate Kit
Catalog #: IQM-MIP1b-5 -- 5 Plate Kit
Please email us at cs@medikonia.com for any enquiry. To place an order, please include the catalog number(s) of the product(s) in the email.