+852 2866 8995 General Enquiry: cs@medikonia.com | Support: support@medikonia.com

RayBiotech Human L1CAM IQELISA™ Kit

Immuno-PCR IQELISA™ Catalog #: IQH-L1CAM

Product description Order information Resources Panel

Human L1CAM IQELISA™ Kit

RayBio® Human Immunoquantitative (PCR-Based) L1CAM ELISA Kit for cell culture supernatants, plasma, and serum samples. 20-25 business day lead time

 

Specifications

Size

1 Plate Kit, 2 Plate Kit, 5 Plate Kit

Species

Human

Quantitative/Semi-Quantitative   

Quantitative

Protein Name / Synonyms

Neural cell adhesion molecule L1 (N-CAM-L1) (NCAM-L1) (CD antigen CD171)

Accession Number

P32004

Gene Symbols

L1CAM|CAML1|MIC5

Gene Id

3897

Compatible Sample Types

Cell Culture Supernatants, Plasma, Serum

Solid Support

96-well Microplate **The PCR plate used is a 0.2mL, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600)

Method Of Detection

qPCR

Design Principle

Sandwich-based

Sensitivity

0.08 pg/ml (Anticipated minimum sensitivity. Assay may detect lower levels of antigen.)

 

Introduction

The RayBio® Immuno Quantitative Enzyme Linked ImumunoSorbent Assay (IQELISA™) is an innovative new assay that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of lower sample volumes while also providing more sensitivity. The RayBio® Human L1CAM IQELISA™ Kit is a modified ELISA assay with high sensitivity qPCR readout for the quantitative measurement of Human L1CAM in serum, plasma, and cell culture supernatants. This assay employs an antibody specific for Human L1CAM coated on a 96-well PCR plate. Standards and samples are pipetted into the wells and L1CAM present in a sample is bound to the wells by the immobilized antibody. The wells are washed and a detection affinity molecule is added to the plates. After washing away unbound detection affinity molecule, primers and a PCR master mix are added to the wells and data is collected using qPCR. Ct values obtained from the qPCR are then used to calculate the amount of antigen contained in each sample, where lower Ct values indicate a higher concentration of antigen.

 

Typical Data

 

Application Notes

Kit Components

  • - L1CAM Microplate (Item A)**: 96 well PCR plate coated with anti-Human L1CAM

  • - Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution

  • - Standards (Item C): 2 vials of recombinant Human L1CAM

  • - Assay Diluent B (Item E): 15 ml of 5x concentrated buffer

  • - Detection Affinity Reagent for L1CAM (Item F): 2 vials of a 4x concentrated solution of anti-Human L1CAM affinity reagent

  • - IQELISA™ Detection Reagent (Item G): 1 ml of a 10x concentrated stock

  • - Primer Solution (Item I): 1.5 ml vial

  • - PCR Master Mix (Item J): 1.4 ml vial

  • - PCR Preparation buffer (Item K): 1 ml vial of 10x concentrated buffer

  • - Final Wash Buffer (Item L): 10 ml vial of 10x concentrated buffer

**The PCR plate used is a 0.2 ml, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600). Please ensure compatibility with your PCR machine prior to purchase. For additional information contact technical support (cs@medikonia.com).

 

Other Materials Protocol

  • Real-time PCR instrument, Bio-Rad recommended

  • Precision pipettes to deliver 2 µl to 1 ml volumes

  • Adjustable 1-25 ml pipettes for reagent preparation

  • 100 ml and 1 liter graduated cylinders

  • Absorbent paper

  • Distilled or deionized water

  • Log-log graph paper or computer and software for data analysis

  • Tubes to prepare standard or sample dilutions

  • Heating block or water bath capable of 80°C

 

Protocol Outline

 

  • 1. Prepare all reagents, samples and standards as instructed

  • 2. Add 25 µl standard or sample to each well. Incubate for 1.5 - 2.5 hours at room temperature

  • 3. Add 25 µl detection antibody to each well. Incubate 1 hour at room temperature

  • 4. Add 50 µl of IQELISA™ Detection Reagent to each well. Incubate 1 hour

  • 5. Add 10 µl Primer solution and 10 µl of PCR master mix to each well

  • 6. Run real-time PCR

 

Storage/Stability

May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.

Catalog #: IQH-L1CAM-1 -- 1 Plate Kit

Catalog #: IQH-L1CAM-2 -- 2 Plate Kit

Catalog #: IQH-L1CAM-5 -- 5 Plate Kit

 

Please email us at cs@medikonia.com for any enquiry. To place an order, please include the catalog number(s) of the product(s) in the email.