+852 2866 8995 General Enquiry: cs@medikonia.com | Support: support@medikonia.com

RayBiotech Human IL-1 beta/IL-1 F2 IQELISA™ Kit

Immuno-PCR IQELISA™ Catalog #: IQH-IL1B

Product description Order information Resources Panel

Human IL-1 beta/IL-1 F2 IQELISA™ Kit

RayBio® Human Immunoquantitative (PCR-Based) IL-1 beta/IL-1 F2 ELISA Kit for cell culture supernatants, plasma, and serum samples.

 

Specifications

Size

1 Plate Kit, 2 Plate Kit, 5 Plate Kit

Species

Human

Quantitative/Semi-Quantitative

Quantitative

Protein Name / Synonyms

Interleukin-1 beta (IL-1 beta) (Catabolin)

Accession Number

P01584

Gene Symbols

IL1B|IL1F2

Gene Id

3553

Compatible Sample Types

Cell Culture Supernatants, Plasma, Serum

Solid Support

96-well Microplate **The PCR plate used is a 0.2mL, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600)

Method Of Detection

qPCR

Design Principle

Sandwich-based

Sensitivity

0.0064 pg/ml

Detection Range

0.0064 pg/ml - 100pg/ml

Recommended Dilution (Serum/Plasma)   

2-10 fold

 

Introduction

The RayBio® Immuno Quantitative Enzyme Linked ImumunoSorbent Assay (IQELISA™) is an innovative new assay that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of lower sample volumes while also providing more sensitivity. The RayBio® Human IL-1 Beta IQELISA™ Kit is a modified ELISA assay with high sensitivity qPCR readout for the quantitative measurement of Human IL-1 Beta in serum, plasma, and cell culture supernatants. This assay employs an antibody specific for Human IL-1 Beta coated on a 96-well PCR plate. Standards and samples are pipetted into the wells and IL-1 Beta present in a sample is bound to the wells by the immobilized antibody. The wells are washed and a detection affinity molecule is added to the plates. After washing away unbound detection affinity molecule, primers and a PCR master mix are added to the wells and data is collected using qPCR. Ct values obtained from the qPCR are then used to calculate the amount of antigen contained in each sample, where lower Ct values indicate a higher concentration of antigen.

 

Standard Curves

Typical Data

 

Spiking & Recovery Results

Serum spike tests show recovery is 107% with a range of 120% to 94%

 

Application Notes

  • - IL-1 Beta Microplate (Item A)**: 96 well PCR plate coated with anti-Human IL-1 Beta

  • - Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution

  • - Standards (Item C): 2 vials of recombinant Human IL-1 Beta

  • - Assay Diluent B (Item E): 15 ml of 5x concentrated buffer

  • - Detection Affinity Reagent for IL-1 Beta (Item F): 2 vials of a 4x concentrated solution of anti-Human IL-1 Beta affinity reagent

  • - IQELISA™ Detection Reagent (Item G): 1 ml of a 10x concentrated stock

  • - Primer Solution (Item I): 1.5 ml vial

  • - PCR Master Mix (Item J): 1.4 ml vial

  • - PCR Preparation buffer (Item K): 1 ml vial of 10x concentrated buffer

  • - Final Wash Buffer (Item L): 10 ml vial of 10x concentrated buffer

**The PCR plate used is a 0.2 ml, non-skirted 96-well plate (ThermoFisher, cat. no.: AB0600). Please ensure compatibility with your PCR machine prior to purchase. For additional information contact technical support (cs@medikonia.com).

 

Other Materials Required

  • - Real-time PCR instrument, Bio-Rad recommended

  • - Precision pipettes to deliver 2 µl to 1 ml volumes

  • - Adjustable 1-25 ml pipettes for reagent preparation

  • - 100 ml and 1 liter graduated cylinders

  • - Absorbent paper

  • - Distilled or deionized water

  • - Log-log graph paper or computer and software for data analysis

  • - Tubes to prepare standard or sample dilutions

  • - Heating block or water bath capable of 80°C

 

Protocol Outline

  • 1. Prepare all reagents, samples and standards as instructed

  • 2. Add 25µl standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C

  • 3. Add 25 µl detection affinity reagent to each well. Incubate 1 hour at room temperature

  • 4. Add 25µL of IQELISA™ Detection Reagent to each well. Incubate 1 hour

  • 5. Add 15µL Primer solution 10µL of PCR master mix to each well

  • 6. Run real-time PCR

 

Storage/Stability

May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.

Catalog #: IQH-IL1B-1 -- 1 Plate Kit

Catalog #: IQH-IL1B-2 -- 2 Plate Kit

Catalog #: IQH-IL1B-5 -- 5 Plate Kit

 

Please email us at cs@medikonia.com for any enquiry. To place an order, please include the catalog number(s) of the product(s) in the email.