DeNovix DS-11 Series Spectrophotometer / Fluorometer

DeNovix takes spectrophotometry to a whole new level of performance with the DS-11 Series. This easy-to-use, compact instrument delivers full spectrum UV-Vis analysis and fluorescence capability making it ideal for rapid nucleic acid and protein quantification. Our customers agree and have made the DeNovix DS-11 Series the twice winner of the Reviewers' Choice Product of the Year and the first life science instrument to be awarded the Platinum Seal of Quality by SelectScience based on scientist reviews for outstanding ease-of-use, performance, service and technical support.

Product description Order information Resources Panel

Award Winning Performance

 

DeNovix takes spectrophotometry to a whole new level of performance with the DS-11 Series. This easy-to-use, compact instrument delivers full spectrum UV-Vis analysis and fluorescence capability making it ideal for rapid nucleic acid and protein quantification. Our customers agree and have made the DeNovix DS-11 Series the twice winner of the Reviewers’ Choice Product of the Year and the first life science instrument to be awarded the Platinum Seal of Quality by SelectScience based on scientist reviews for outstanding ease-of-use, performance, service and technical support.

 

Best in Class 1 uL Sensitivity and Highest Absorbance Capability

 

DS-11 Series Spectrophotometers set the industry standard for the lower detection limits of 0.5 -1.0 uL UV-Vis sample analysis. Detect to 0.75 ng/uL dsDNA, 0.60 ng/uL RNA or 0.04 mg/mL BSA.  The DS-11 can measure samples with absorbance values as high as 750 absorbance units (at a 1 cm equivalent path length). This translates into 1125 mg/ml of BSA protein or 37500 ng/uL of dsDNA. This ultra high absorbance capability is achieved by using a remarkably small pathlength enabled by our SmartPath™ technology.

 

 

Easy to Learn. Fast to Use.

 

The DS-11 Series instruments feature the most powerful and intuitive software of its type. EasyApps™ software is designed by life scientists and combines with an intuitive touchscreen interface to ensure error-free operation and sample to data in under 3 seconds. Every instrument is ready to go right out of the box – no PC set-up or software installation required.

 

 

The Only All-In-One Microvolume and Cuvette Absorbance with Fluorescence Design

 

With the DS-11 Series you can equip your lab for today’s quantification requirements and for future assay challenges. Combine the ease of use, wide dynamic range and contamination information of UV-Vis with the enhanced sensitivity and specific quantification of fluorescence for total sample quality control.

Absorbance and Fluorescence quantification are unique but complementary methods for assessing concentration and quality of biological samples. The multi-award winning DS-11 Series of 1 µL Spectrophotometers and Fluorometers provides the most sensitive and widest dynamic range for UV-Vis absorbance and fluorescence capability in one combined instrument.

 

 

21 CFR Part 11 Compliance Ready

 

EasyApps Secure provides an optional suite of software controls that allow regulated GxP facilities to easily add DS-11 Series instruments to their compliant workflows (view the compliance statement). The software is fully integrated within the on-board operating system and includes a range of features essential to ensuring compliance, including:

  • Password protected system access
  • Integrated electronic signature controls
  • Comprehensive user account management
  • Secure audit trail recording
  • Advanced data handling and export tools

 

 

 

 

Spectrophotometer Microvolume Mode (DS-11, DS-11+, DS-11 FX, DS-11 FX+)

 

Minimum Sample Size 0.5 µL
Pathlength 0.5 mm (auto ranging to 0.02 mm)
Light Source Pulsed Xenon flash lamp
Detector Type 2048 element CCD
Wavelength Range 190-840 nm
Wavelength Accuracy 0.5 nm
Wavelength Precision 0.14 nm
Spectral Resolution 1.5 nm (FWHM at Hg 253.7 nm)
Absorbance Precision 0.015 AU (1 cm) or 1%, whichever is greater
Absorbance Accuracy 1.5% at 0.75 AU at 260 nm
Absorbance Range 0.015 – 750 (1 cm equivalent)
Detection limit 0.04 mg/mL BSA; 0.75 ng/µL dsDNA
Maximum Concentration 1125 mg/mL BSA; 37500 ng/µL dsDNA
Lower Sample Surface Material of Construction 303 stainless steel and sapphire window
Upper Sample Surface Material of Construction 303 stainless steel and quartz fiber

 

 

FX Module: Upgrade to Fluorescence

 

Instantly add the power of fluorescence detection to any DeNovix DS-11, DS-11+ or DS-C Spectrophotometer. The FX Module uses the same fluorescence detection as the DS-11 FX, DS-11 FX+ and QFX. Simply plug in this USB powered accessory and DeNovix fluorometric EasyApps are immediately enabled. With four user-selectable LEDs, the easy-to-use apps are compatible with a wide range of commercially available assays including those designed for Thermo Fisher’s Qubit™ fluorometer and Promega’s Quantus™ fluorometer platforms.

 

Absorbance and Fluorescence Quantification Infographic

 

Absorbance and Fluorescence quantification are unique but complementary methods for assessing concentration and quality of biological samples. The multi-award winning DS-11 Series of 1 µL Spectrophotometers and Fluorometers provides the most sensitive and widest dynamic range for UV-Vis absorbance and fluorescence capability in one combined instrument.

Selecting the appropriate quantification methods for biological samples is an important consideration in any quality control process. Download our infographic featuring comparisons of the key features of absorbance and fluorescence quantification and information on when each method should be applied or the results combined.

 

 


 

Download the Product Brochure here for more information.

For more information or ordering, please email us at cs@medikonia.com