+852 2866 8995 General Enquiry: cs@medikonia.com | Support: support@medikonia.com

Lonza ELx808™ Incubating Absorbance Plate Reader

The ELx808TM Incubating Absorbance Microplate Reader has been validated as part of Lonza's quantitative endotoxin detection system interfacing with Lonza's WinKQCLTM Endotoxin Detection and Analysis Software.

Product description Order information Resources Panel

Product Overview

 

The ELx808TM Incubating Absorbance Microplate Reader has been validated as part of Lonza's quantitative endotoxin detection system interfacing with Lonza's WinKQCLTM Endotoxin Detection and Analysis Software. This 96-well microplate reader features 4 insulated incubating zones, providing well-to-well temperature uniformity available on the market. Utilizing interference filters instead of monochromators, the reader is optimized for the LAL-based endotoxin tests and comes pre-configured with the following interference filters: 340nm, 405nm, 450nm, 490nm, and 630nm. The ELx808TM Reader seamlessly interfaces with Lonza's  WinKQCLTM Endotoxin Detection and Analysis Software. 

For the kinetic and endpoint LAL assays, the ELx808TM Reader is highly reliable and easy to use. It features fully-automated kinetic reads of the 96-well plate via the WinKQCLTM Software. This reader can also be used as a standard spectrophotometer and results can be read from the QCL-1000TM Endpoint Chromogenic LAL Assay and ELISA Assays. 

On-site service and preventive maintenance contracts are available to ensure that your instrument is working properly. 

 

 

ELx808TM Absorbance Reader Specifications

 

Wavelength Range 340 to 900 nm
Filters Supplied 340, 405, 450, 490, and 630 nm
Absorbance Range

0.000 to 4.000 OD @ 400 to 900 nm

0.000 to 3.000 OD @ 340 to 400 nm

Temperature Control  4°C above ambient to 50°C

 

 

 Read Method  Kinetic or endpoint under WinKQCLTM Control
 Light Source  Tungsten Halogen Bulb
 Dimensions  16-inches deep x 15.5-inches wide x 8.75-inches high (40.6 cm x 39.4 cm x 22.2 cm)
 Weight  35 lb (15.9 kg)

 

 

Benefits

 

  • Excellent temperature uniformity
  • Precise and accurate
  • Cost effective
  • Filter-based reader
  • Special reader configuration optimized for LAL testing 
  • Vendor QC release testing specific for endotoxin detection
  • Three year warranty

 

Applications

 

  • Parenterals
  • Biologics
  • Medical Devices
  • Dialysis
  • Compounding
  • Water Analysis
  • R&D 

Catalog #: 25-315S

 


 

Please email us at cs@medikonia.com for any enquiry. To place an order, please include the catalog number(s) of the product(s) in the email.